A dynamic current allocation algorithm for alienation coefficient based busbar fault discriminatorHossain et al., 2017
- Document ID
- 17532560286984137039
- Author
- Hossain M
- Mittal L
- Rastgoufard P
- Publication year
- Publication venue
- 2017 19th International Conference on Intelligent System Application to Power Systems (ISAP)
External Links
Snippet
Alienation coefficient based busbar fault discriminator is one of the latest methods used to supervise the busbar differential protection schemes for detecting internal and external faults correctly. This fault discriminator uses alienation coefficient of current signals obtained from …
- 238000004088 simulation 0 abstract description 7
Classifications
-
- H—ELECTRICITY
- H02—GENERATION; CONVERSION OR DISTRIBUTION OF ELECTRIC POWER
- H02H—EMERGENCY PROTECTIVE CIRCUIT ARRANGEMENTS
- H02H1/00—Details of emergency protective circuit arrangements
- H02H1/0007—Details of emergency protective circuit arrangements concerning the detecting means
-
- H—ELECTRICITY
- H02—GENERATION; CONVERSION OR DISTRIBUTION OF ELECTRIC POWER
- H02H—EMERGENCY PROTECTIVE CIRCUIT ARRANGEMENTS
- H02H7/00—Emergency protective circuit arrangements specially adapted for specific types of electric machines or apparatus or for sectionalised protection of cable or line systems, and effecting automatic switching in the event of an undesired change from normal working conditions
- H02H7/26—Sectionalised protection of cable or line systems, e.g. for disconnecting a section on which a short-circuit, earth fault, or arc discharge has occured
- H02H7/261—Sectionalised protection of cable or line systems, e.g. for disconnecting a section on which a short-circuit, earth fault, or arc discharge has occured involving signal transmission between at least two stations
-
- H—ELECTRICITY
- H02—GENERATION; CONVERSION OR DISTRIBUTION OF ELECTRIC POWER
- H02H—EMERGENCY PROTECTIVE CIRCUIT ARRANGEMENTS
- H02H3/00—Emergency protective circuit arrangements for automatic disconnection directly responsive to an undesired change from normal electric working condition with or without subsequent reconnection integrated protection
-
- H—ELECTRICITY
- H04—ELECTRIC COMMUNICATION TECHNIQUE
- H04L—TRANSMISSION OF DIGITAL INFORMATION, e.g. TELEGRAPHIC COMMUNICATION
- H04L12/00—Data switching networks
- H04L12/28—Data switching networks characterised by path configuration, e.g. local area networks [LAN], wide area networks [WAN]
-
- H—ELECTRICITY
- H02—GENERATION; CONVERSION OR DISTRIBUTION OF ELECTRIC POWER
- H02J—CIRCUIT ARRANGEMENTS OR SYSTEMS FOR SUPPLYING OR DISTRIBUTING ELECTRIC POWER; SYSTEMS FOR STORING ELECTRIC ENERGY
- H02J3/00—Circuit arrangements for ac mains or ac distribution networks
-
- H—ELECTRICITY
- H04—ELECTRIC COMMUNICATION TECHNIQUE
- H04B—TRANSMISSION
- H04B2203/00—Indexing scheme relating to line transmission systems
- H04B2203/54—Aspects of powerline communications not already covered by H04B3/54 and its subgroups
- H04B2203/5462—Systems for power line communications
- H04B2203/5495—Systems for power line communications having measurements and testing channel
Similar Documents
Publication | Publication Date | Title |
---|---|---|
Nayak et al. | Wide-area measurement-based backup protection for power network with series compensation | |
Muda et al. | Sequence currents based adaptive protection approach for DNs with distributed energy resources | |
Chaitanya et al. | An improved differential protection scheme for micro-grid using time-frequency transform | |
Ghiasi et al. | Enhancing power grid stability: design and integration of a fast bus tripping system in protection relays | |
Dang et al. | An adaptive protection method for the inverter dominated microgrid | |
Karimi et al. | A protection strategy for inverter-interfaced islanded microgrids with looped configuration | |
Laaksonen | New multi-criteria-based algorithm for islanding detection in smart grids | |
Li et al. | Circulating unbalanced currents of EHV/UHV untransposed double-circuit lines and their influence on pilot protection | |
Prasai et al. | Protection of meshed microgrids with communication overlay | |
Anudeep et al. | Differential power based selective phase tripping for fault-resilient microgrid | |
Wheeler et al. | Assessment of distributed generation influences on fuse-recloser protection systems in radial distribution networks | |
Sidhu et al. | A power transformer protection technique with stability during current transformer saturation and ratio-mismatch conditions | |
Eissa et al. | A new developed smart grid protection technique with wind farms based on positive sequence impedances and current angles | |
Ansari et al. | Fault detection for microgrid feeders using features based on superimposed positive-sequence power | |
Manditereza et al. | Introducing a new type of protection zone for the smart grid incorporating distributed generation | |
Makwana et al. | Improvement in recloser–fuse coordination technique based on modification factor | |
Hossain et al. | A dynamic current allocation algorithm for alienation coefficient based busbar fault discriminator | |
Ramasubramanian et al. | Ability of positive sequence aggregated distributed energy resource model to represent unbalanced tripping of distribution inverters | |
Usta et al. | A new directional relaying scheme for the protection of active distribution networks against asymmetric faults | |
Sanati et al. | An adaptive overcurrent protection for solar-based DC microgrids using IEC 61850 | |
Uddin et al. | An FPGA-based cost-effective digital differential relay for wind farm protection | |
Abdelaziz et al. | Distance protection for multi-terminal transmission lines | |
Hossain et al. | Comparative analysis of fault discrimination algorithms on sensitivity to high impedance busbar faults | |
Hossain et al. | A Current Transformer (CT) Saturation Detection Method for Bus Differential Protection | |
Huang et al. | Protection scheme for active distribution networks using positive-sequence components |