Effect of prime mover's characteristics on the survivability of a synchronous generator during transient overload conditions

Choi et al., 2019

Document ID
13301288039384568970
Author
Choi J
Illindala M
Publication year
Publication venue
2019 IEEE/IAS 55th Industrial and Commercial Power Systems Technical Conference (I&CPS)

External Links

Snippet

Recently, prime-mover stalling phenomenon was observed in a synchronous generator- based DER for large step load changes during experimental testing at the CERTS Microgrid. It is found to highly impact the generator's survivability during transient overload conditions …
Continue reading at ieeexplore.ieee.org (other versions)

Classifications

    • FMECHANICAL ENGINEERING; LIGHTING; HEATING; WEAPONS; BLASTING ENGINES OR PUMPS
    • F02COMBUSTION ENGINES; HOT-GAS OR COMBUSTION-PRODUCT ENGINE PLANTS
    • F02CGAS-TURBINE PLANTS; AIR INTAKES FOR JET-PROPULSION PLANTS; CONTROLLING FUEL SUPPLY IN AIR-BREATHING JET-PROPULSION PLANTS
    • F02C9/00Controlling gas-turbine plants; Controlling fuel supply in air- breathing jet-propulsion plants
    • F02C9/26Control of fuel supply
    • F02C9/42Control of fuel supply specially adapted for the control of two or more plants simultaneously
    • HELECTRICITY
    • H02GENERATION; CONVERSION OR DISTRIBUTION OF ELECTRIC POWER
    • H02PCONTROL OR REGULATION OF ELECTRIC MOTORS, ELECTRIC GENERATORS OR DYNAMO-ELECTRIC CONVERTERS; CONTROLLING TRANSFORMERS, REACTORS OR CHOKE COILS
    • H02P9/00Arrangements for controlling electric generators for the purpose of obtaining a desired output
    • H02P9/10Control effected upon generator excitation circuit to reduce harmful effects of overloads or transients, e.g. sudden application of load, sudden removal of load, sudden change of load
    • FMECHANICAL ENGINEERING; LIGHTING; HEATING; WEAPONS; BLASTING ENGINES OR PUMPS
    • F01MACHINES OR ENGINES IN GENERAL; ENGINE PLANTS IN GENERAL; STEAM ENGINES
    • F01DNON-POSITIVE DISPLACEMENT MACHINES OR ENGINES, e.g. STEAM TURBINES
    • F01D15/00Adaptations of machines or engines for special use; Combinations of engines with devices driven thereby
    • F01D15/10Adaptations for driving, or combinations with, electric generators
    • FMECHANICAL ENGINEERING; LIGHTING; HEATING; WEAPONS; BLASTING ENGINES OR PUMPS
    • F02COMBUSTION ENGINES; HOT-GAS OR COMBUSTION-PRODUCT ENGINE PLANTS
    • F02CGAS-TURBINE PLANTS; AIR INTAKES FOR JET-PROPULSION PLANTS; CONTROLLING FUEL SUPPLY IN AIR-BREATHING JET-PROPULSION PLANTS
    • F02C7/00Features, components parts, details or accessories, not provided for in, or of interest apart form groups F02C1/00 - F02C6/00; Air intakes for jet-propulsion plants
    • F02C7/26Starting; Ignition

Similar Documents

Publication Publication Date Title
Gaonkar et al. Modeling and simulation of microturbine based distributed generation system
Choi et al. Effect of prime mover's characteristics on the survivability of a synchronous generator-based distributed energy resource during transient overload conditions
Feehally et al. The doubly fed induction machine as an aero generator
JP5721828B2 (en) Parallel operation control method and control system between different types of power generators
Torres et al. Inverter-based diesel generator emulator for the study of frequency variations in a laboratory-scale autonomous power system
Choi et al. Survivability of synchronous generator-based distributed energy resources for transient overload conditions in a microgrid
Choi et al. Survivability of prime-mover powered inverter-based distributed energy resources during microgrid islanding
Vijlee et al. Directly-coupled gas turbine permanent magnet generator sets for prime power generation on board electric ships
Choi et al. Effect of prime mover's characteristics on the survivability of a synchronous generator during transient overload conditions
Hutten et al. Torsional interharmonic interaction study of 75 MW direct-driven VSDS motor compressor trains for LNG duty
Bladh et al. Torsional stability of hydropower units under influence of subsynchronous oscillations
Quinonez-Varela et al. Development of a small-scale generator set model for local network voltage and frequency stability analysis
Guda Modeling and power managenent of a hybrid wind-microturbine power generation system
Zharkov et al. The analysis of the reactive launch of three-stage synchronous generator for aviation starter-generator device
Correa et al. Mechanical power-hardware-in-the-loop: Emulation of an aeroderivative twin-shaft turbine engine
CN114556733A (en) Load predictor system for a generator system
KR20230131122A (en) Power systems having an inertia assembly and methods for operation
Owen et al. Induction generator applications for petroleum and chemical plants
Abdollahi et al. Dynamic Modelling of Micro-Turbine Generation Systems Using Matlab/Simulink.
Tweedy et al. Electromechanical Analysis of Low Voltage Faults in a Magnetically Coupled Synchronous Generator Set
Tian et al. Reciprocating engine step load response in islanded power generation
Elsebaay et al. Analyzing the Effect of Motor Loads and Introducing a Method for Selection of Electric Generator Power Rating
Cassimere et al. Power oscillation impact on generator/turbine interaction for an isolated power system
Chan Synchronous Machines
da Silva Neto et al. Control of power circuit interface of a flywheel-based energy storage system