Wang et al., 2019 - Google Patents
On‐site partial discharge test technology of converter transformerWang et al., 2019
View PDF- Document ID
- 10440016387595921293
- Author
- Wang W
- Yang D
- Li R
- Yan L
- Guo R
- Zhang N
- Tao W
- Publication year
- Publication venue
- The Journal of Engineering
External Links
Snippet
The rectifier transformer is the power transformer of the rectifier equipment. The characteristic of the rectifier device is the AC input, DC output by rectifying the original. Converter transformer and voltage regulation transformer connect through oil and gas …
- 238000005516 engineering process 0 title description 4
Classifications
-
- G—PHYSICS
- G01—MEASURING; TESTING
- G01R—MEASURING ELECTRIC VARIABLES; MEASURING MAGNETIC VARIABLES
- G01R31/00—Arrangements for testing electric properties; Arrangements for locating electric faults; Arrangements for electrical testing characterised by what is being tested not provided for elsewhere
- G01R31/02—Testing of electric apparatus, lines or components, for short-circuits, discontinuities, leakage of current, or incorrect line connection
- G01R31/027—Testing of transformers
-
- G—PHYSICS
- G01—MEASURING; TESTING
- G01R—MEASURING ELECTRIC VARIABLES; MEASURING MAGNETIC VARIABLES
- G01R31/00—Arrangements for testing electric properties; Arrangements for locating electric faults; Arrangements for electrical testing characterised by what is being tested not provided for elsewhere
- G01R31/12—Testing dielectric strength or breakdown voltage; Testing or monitoring effectiveness or level of insulation, e.g. of a cable or of an apparatus, for example using partial discharge measurements; Electrostatic testing
- G01R31/1227—Testing dielectric strength or breakdown voltage; Testing or monitoring effectiveness or level of insulation, e.g. of a cable or of an apparatus, for example using partial discharge measurements; Electrostatic testing of components, parts or materials
- G01R31/1263—Testing dielectric strength or breakdown voltage; Testing or monitoring effectiveness or level of insulation, e.g. of a cable or of an apparatus, for example using partial discharge measurements; Electrostatic testing of components, parts or materials of solid or fluid materials, e.g. insulation films, bulk material; of semiconductors or LV electronic components or parts; of cable, line or wire insulation
-
- G—PHYSICS
- G01—MEASURING; TESTING
- G01R—MEASURING ELECTRIC VARIABLES; MEASURING MAGNETIC VARIABLES
- G01R31/00—Arrangements for testing electric properties; Arrangements for locating electric faults; Arrangements for electrical testing characterised by what is being tested not provided for elsewhere
- G01R31/02—Testing of electric apparatus, lines or components, for short-circuits, discontinuities, leakage of current, or incorrect line connection
- G01R31/024—Arrangements for indicating continuity or short-circuits in electric apparatus or lines, leakage or ground faults
Similar Documents
| Publication | Publication Date | Title |
|---|---|---|
| Alfalahi et al. | Supraharmonics in power grid: Identification, standards, and measurement techniques | |
| Kunicki et al. | Measurements on partial discharge in on‐site operating power transformer: A case study | |
| Sima et al. | Statistical analysis on measured lightning overvoltage surges in a 110 kV air‐insulated substation | |
| Lu et al. | Effects of converter harmonic voltages on transformer insulation ageing and an online monitoring method for interlayer insulation | |
| Cheng et al. | Proposed methodology for online frequency response analysis based on magnetic coupling to detect winding deformations in transformers | |
| He et al. | On‐site partial discharge detection of power cables using a novel DAC technique supplied by a capacitor bank | |
| Sant’Ana et al. | Early detection of insulation failures on electric generators through online Frequency Response Analysis | |
| Ma et al. | Research on the fault diagnosis method for slip ring device in doubly‐fed induction generators based on vibration | |
| Peng et al. | Influence of sympathetic inrush on voltage dips caused by transformer energisation | |
| Rajamani et al. | Interturn short diagnosis in small transformers through impulse injection: on‐line on‐load self‐impedance transfer function approach | |
| Ushakov et al. | Transformer Condition Control | |
| Bharti et al. | No‐load performance study of 1200 kV Indian UHVAC transmission system | |
| Li et al. | Impact analysis of the capacitive coupling sensor on bushing external insulation | |
| Karafotis et al. | Power quality monitoring and evaluation in power systems under non‐stationary conditions using wavelet packet transform | |
| Bin et al. | Research on mechanical fault diagnosis method of power transformer winding | |
| Wang et al. | On‐site partial discharge test technology of converter transformer | |
| Li et al. | Study of frequency domain dielectric properties of vegetable oil and mineral oil transformer | |
| Chang et al. | Fuzzy theory-based partial discharge technique for operating state diagnosis of high-voltage motor | |
| Shi et al. | Travelling waves‐based identification of sub‐health condition of feeders in power distribution system | |
| Yang et al. | Transient overvoltage response performance of transformer windings with short‐circuit fault | |
| Xia et al. | Simulation and partial discharge detection for typical defects of 10 kV cable the joint | |
| Du et al. | Harmonic voltage measurement based on capacitive equipment dielectric equivalent model and responding current | |
| Manjunath et al. | Mitigation of CM conducted EMI in flyback converter using balancing capacitors | |
| Wang et al. | Electromagnetic disturbance characteristic of typical high voltage switchgear interruption process in offshore wind farm based on integrated conduction model | |
| Li et al. | Influence of untested winding in FRA test for winding diagnosis |