Tan et al., 2007 - Google Patents
Two electrodes low voltage input EEG amplifier for brain-computer-interfaceTan et al., 2007
View PDF- Document ID
- 9072151416735583001
- Author
- Tan Y
- Ibrahim F
- Moghavvemi M
- Publication year
- Publication venue
- 2007 International Conference on Intelligent and Advanced Systems
External Links
Snippet
This paper describes the development of a bi-polar EEG amplifier designed specifically for use in a brain-computer-interface (BCI). The design principle of amplifier is base on a differential amplifier followed with multiple gain amplifier units. The amplifier gain is easily …
- 239000003990 capacitor 0 description 14
Classifications
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61B—DIAGNOSIS; SURGERY; IDENTIFICATION
- A61B5/00—Detecting, measuring or recording for diagnostic purposes; Identification of persons
- A61B5/04—Detecting, measuring or recording bioelectric signals of the body of parts thereof
- A61B5/0476—Electroencephalography
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61B—DIAGNOSIS; SURGERY; IDENTIFICATION
- A61B5/00—Detecting, measuring or recording for diagnostic purposes; Identification of persons
- A61B5/04—Detecting, measuring or recording bioelectric signals of the body of parts thereof
- A61B5/0402—Electrocardiography, i.e. ECG
- A61B5/0428—Input circuits specially adapted therefor
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61B—DIAGNOSIS; SURGERY; IDENTIFICATION
- A61B5/00—Detecting, measuring or recording for diagnostic purposes; Identification of persons
- A61B5/04—Detecting, measuring or recording bioelectric signals of the body of parts thereof
- A61B5/0488—Electromyography
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61B—DIAGNOSIS; SURGERY; IDENTIFICATION
- A61B5/00—Detecting, measuring or recording for diagnostic purposes; Identification of persons
- A61B5/04—Detecting, measuring or recording bioelectric signals of the body of parts thereof
- A61B5/04001—Detecting, measuring or recording bioelectric signals of the body of parts thereof adapted to neuroelectric signals, e.g. nerve impulses
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61B—DIAGNOSIS; SURGERY; IDENTIFICATION
- A61B5/00—Detecting, measuring or recording for diagnostic purposes; Identification of persons
- A61B5/72—Signal processing specially adapted for physiological signals or for diagnostic purposes
- A61B5/7235—Details of waveform analysis
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61B—DIAGNOSIS; SURGERY; IDENTIFICATION
- A61B5/00—Detecting, measuring or recording for diagnostic purposes; Identification of persons
- A61B5/04—Detecting, measuring or recording bioelectric signals of the body of parts thereof
- A61B5/04012—Analysis of electro-cardiograms, electro-encephalograms, electro-myograms
- A61B5/04017—Analysis of electro-cardiograms, electro-encephalograms, electro-myograms by using digital filtering
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61B—DIAGNOSIS; SURGERY; IDENTIFICATION
- A61B5/00—Detecting, measuring or recording for diagnostic purposes; Identification of persons
- A61B5/05—Detecting, measuring or recording for diagnosis by means of electric currents or magnetic fields; Measuring using microwaves or radiowaves
- A61B5/053—Measuring electrical impedance or conductance of a portion of the body
- A61B5/0531—Measuring skin impedance
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61B—DIAGNOSIS; SURGERY; IDENTIFICATION
- A61B5/00—Detecting, measuring or recording for diagnostic purposes; Identification of persons
- A61B5/72—Signal processing specially adapted for physiological signals or for diagnostic purposes
- A61B5/7232—Signal processing specially adapted for physiological signals or for diagnostic purposes involving compression of the physiological signal, e.g. to extend the signal recording period
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61B—DIAGNOSIS; SURGERY; IDENTIFICATION
- A61B5/00—Detecting, measuring or recording for diagnostic purposes; Identification of persons
- A61B5/72—Signal processing specially adapted for physiological signals or for diagnostic purposes
- A61B5/7203—Signal processing specially adapted for physiological signals or for diagnostic purposes for noise prevention, reduction or removal
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61N—ELECTROTHERAPY; MAGNETOTHERAPY; RADIATION THERAPY; ULTRASOUND THERAPY
- A61N1/00—Electrotherapy; Circuits therefor
- A61N1/18—Applying electric currents by contact electrodes
- A61N1/32—Applying electric currents by contact electrodes alternating or intermittent currents
- A61N1/36—Applying electric currents by contact electrodes alternating or intermittent currents for stimulation, e.g. heart pace-makers
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61B—DIAGNOSIS; SURGERY; IDENTIFICATION
- A61B5/00—Detecting, measuring or recording for diagnostic purposes; Identification of persons
- A61B5/02—Detecting, measuring or recording pulse, heart rate, blood pressure or blood flow; Combined pulse/heart-rate/blood pressure determination; Evaluating a cardiovascular condition not otherwise provided for, e.g. using combinations of techniques provided for in this group with electrocardiography or electroauscultation; Heart catheters for measuring blood pressure
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61B—DIAGNOSIS; SURGERY; IDENTIFICATION
- A61B5/00—Detecting, measuring or recording for diagnostic purposes; Identification of persons
- A61B5/48—Other medical applications
Similar Documents
Publication | Publication Date | Title |
---|---|---|
Jani et al. | Design of a low-power, low-cost ECG & EMG sensor for wearable biometric and medical application | |
Harrison | A versatile integrated circuit for the acquisition of biopotentials | |
Zhang et al. | Design of ultra-low power biopotential amplifiers for biosignal acquisition applications | |
Ng et al. | A compact, low input capacitance neural recording amplifier | |
CN107510454A (en) | Myoelectric signal collection apparatus and system based on multistage filtering | |
Smith et al. | Exploiting electrocorticographic spectral characteristics for optimized signal chain design: A 1.08 W analog front end with reduced ADC resolution requirements | |
Guerrero et al. | Surface EMG multichannel measurements using active, dry branched electrodes | |
KR20180018922A (en) | Improved bio-potential measurement system | |
Viana et al. | A low-power low-noise instrumentation amplifier for wearable applications | |
Su et al. | Wireless ECG detection system with low-power analog front-end circuit and bio-processing ZigBee firmware | |
Lim et al. | A fully integrated electroencephalogram (EEG) analog front-end IC with capacitive input impedance boosting loop | |
Engin et al. | A prototype portable system for EEG measurements | |
Lee et al. | A tunable biquad switched-capacitor amplifier-filter for neural recording | |
JP2019510600A (en) | Digital biopotential acquisition system with 8 channels | |
Chebli et al. | Low noise and high CMRR front-end amplifier dedicated to portable EEG acquisition system | |
Tan et al. | Two electrodes low voltage input EEG amplifier for brain-computer-interface | |
Szakacs-Simon et al. | Signal conditioning techniques for health monitoring devices | |
Kim et al. | Neural recording system with low-noise analog front-end and comparator-based cyclic ADC | |
Sinha et al. | A 22nm±0.95 V CMOS OTA-C front-end with 50/60 Hz notch for biomedical signal acquisition | |
Mollazadeh et al. | From spikes to EEG: Integrated multichannel and selective acquisition of neuropotentials | |
Xu et al. | Low-cost circuit design for eeg signal amplification and extraction | |
Zhang et al. | A neural recording ic design with on-chip CMOS electrode array for brain-machine interface | |
Wu et al. | Research on the Basic Principle of Neural Signal Recording System and Noise Cancellation Method | |
Bharathi et al. | Low Cost Analog EEG Amplifier for Healthcare Applications | |
JP2014151016A (en) | Variable low-pass filter and biological information diagnostic device |