Stachowiak et al., 2007 - Google Patents
Autonomous microfluidic sample preparation system for protein profile-based detection of aerosolized bacterial cells and sporesStachowiak et al., 2007
View PDF- Document ID
- 9002530003955957118
- Author
- Stachowiak J
- Shugard E
- Mosier B
- Renzi R
- Caton P
- Ferko S
- Van de Vreugde J
- Yee D
- Haroldsen B
- VanderNoot V
- Publication year
- Publication venue
- Analytical chemistry
External Links
Snippet
For domestic and military security, an autonomous system capable of continuously monitoring for airborne biothreat agents is necessary. At present, no system meets the requirements for size, speed, sensitivity, and selectivity to warn against and lead to the …
- 102000004169 proteins and genes 0 title abstract description 106
Classifications
-
- G—PHYSICS
- G01—MEASURING; TESTING
- G01N—INVESTIGATING OR ANALYSING MATERIALS BY DETERMINING THEIR CHEMICAL OR PHYSICAL PROPERTIES
- G01N33/00—Investigating or analysing materials by specific methods not covered by the preceding groups
- G01N33/48—Investigating or analysing materials by specific methods not covered by the preceding groups biological material, e.g. blood, urine; Haemocytometers
- G01N33/50—Chemical analysis of biological material, e.g. blood, urine; Testing involving biospecific ligand binding methods; Immunological testing
- G01N33/53—Immunoassay; Biospecific binding assay
- G01N33/569—Immunoassay; Biospecific binding assay for micro-organisms, e.g. protozoa, bacteria, viruses
-
- G—PHYSICS
- G01—MEASURING; TESTING
- G01N—INVESTIGATING OR ANALYSING MATERIALS BY DETERMINING THEIR CHEMICAL OR PHYSICAL PROPERTIES
- G01N33/00—Investigating or analysing materials by specific methods not covered by the preceding groups
- G01N33/48—Investigating or analysing materials by specific methods not covered by the preceding groups biological material, e.g. blood, urine; Haemocytometers
- G01N33/50—Chemical analysis of biological material, e.g. blood, urine; Testing involving biospecific ligand binding methods; Immunological testing
- G01N33/5005—Chemical analysis of biological material, e.g. blood, urine; Testing involving biospecific ligand binding methods; Immunological testing involving human or animal cells
-
- G—PHYSICS
- G01—MEASURING; TESTING
- G01N—INVESTIGATING OR ANALYSING MATERIALS BY DETERMINING THEIR CHEMICAL OR PHYSICAL PROPERTIES
- G01N1/00—Sampling; Preparing specimens for investigation
- G01N1/28—Preparing specimens for investigation including physical details of (bio-)chemical methods covered elsewhere, e.g. G01N33/50, C12Q
- G01N1/40—Concentrating samples
- G01N1/4077—Concentrating samples by other techniques involving separation of suspended solids
-
- G—PHYSICS
- G01—MEASURING; TESTING
- G01N—INVESTIGATING OR ANALYSING MATERIALS BY DETERMINING THEIR CHEMICAL OR PHYSICAL PROPERTIES
- G01N30/00—Investigating or analysing materials by separation into components using adsorption, absorption or similar phenomena or using ion-exchange, e.g. chromatography or field flow fractionation
- G01N30/02—Column chromatography
-
- G—PHYSICS
- G01—MEASURING; TESTING
- G01N—INVESTIGATING OR ANALYSING MATERIALS BY DETERMINING THEIR CHEMICAL OR PHYSICAL PROPERTIES
- G01N27/00—Investigating or analysing materials by the use of electric, electro-chemical, or magnetic means
-
- G—PHYSICS
- G01—MEASURING; TESTING
- G01N—INVESTIGATING OR ANALYSING MATERIALS BY DETERMINING THEIR CHEMICAL OR PHYSICAL PROPERTIES
- G01N21/00—Investigating or analysing materials by the use of optical means, i.e. using infra-red, visible or ultra-violet light
- G01N21/62—Systems in which the material investigated is excited whereby it emits light or causes a change in wavelength of the incident light
-
- B—PERFORMING OPERATIONS; TRANSPORTING
- B01—PHYSICAL OR CHEMICAL PROCESSES OR APPARATUS IN GENERAL
- B01L—CHEMICAL OR PHYSICAL LABORATORY APPARATUS FOR GENERAL USE
- B01L3/00—Containers or dishes for laboratory use, e.g. laboratory glassware; Droppers
- B01L3/50—Containers for the purpose of retaining a material to be analysed, e.g. test tubes
- B01L3/502—Containers for the purpose of retaining a material to be analysed, e.g. test tubes with fluid transport, e.g. in multi-compartment structures
- B01L3/5027—Containers for the purpose of retaining a material to be analysed, e.g. test tubes with fluid transport, e.g. in multi-compartment structures by integrated micro-fluidic structures, i.e. dimensions of channels and chambers are such that surface tension forces are important, e.g. lab-on-a-chip
Similar Documents
| Publication | Publication Date | Title |
|---|---|---|
| Stachowiak et al. | Autonomous microfluidic sample preparation system for protein profile-based detection of aerosolized bacterial cells and spores | |
| McBride et al. | Multiplexed liquid arrays for simultaneous detection of simulants of biological warfare agents | |
| Xiang et al. | An integrated microfabricated device for dual microdialysis and on-line ESI-ion trap mass spectrometry for analysis of complex biological samples | |
| Kim et al. | Multiplexed detection of bacteria and toxins using a microflow cytometer | |
| Zeininger et al. | Rapid detection of Salmonella enterica via directional emission from carbohydrate-functionalized dynamic double emulsions | |
| McBride et al. | Autonomous Detection of Aerosolized Bacillus a nthracis and Yersinia p estis | |
| Breadmore et al. | Recent advances in enhancing the sensitivity of electrophoresis and electrochromatography in capillaries and microchips (2006–2008) | |
| Shlyapnikov et al. | Rapid simultaneous ultrasensitive immunodetection of five bacterial toxins | |
| Jing et al. | Microfluidic device for efficient airborne bacteria capture and enrichment | |
| Kline et al. | ABO, D blood typing and subtyping using plug-based microfluidics | |
| Tavares et al. | Paper spray tandem mass spectrometry based on molecularly imprinted polymer substrate for cocaine analysis in oral fluid | |
| US20080181821A1 (en) | Microfluidic chips for allergen detection | |
| US10001496B2 (en) | Systems for allergen detection | |
| Ragab et al. | Recent advances and applications of microfluidic capillary electrophoresis: a comprehensive review (2017–mid 2019) | |
| Cheow et al. | Continuous signal enhancement for sensitive aptamer affinity probe electrophoresis assay using electrokinetic concentration | |
| Verbarg et al. | Catch and release: integrated system for multiplexed detection of bacteria | |
| Niu et al. | Femtomolar detection of lipopolysaccharide in injectables and serum samples using aptamer-coupled reduced graphene oxide in a continuous injection-electrostacking biochip | |
| Vakh et al. | Flow analysis: A novel approach for classification | |
| Kim et al. | Integrated magnetic bead–quantum dot immunoassay for malaria detection | |
| Xu et al. | Binding-induced DNA dissociation assay for small molecules: sensing aflatoxin B1 | |
| US8617903B2 (en) | Methods for allergen detection | |
| Hindson et al. | Development of an automated sample preparation module for environmental monitoring of biowarfare agents | |
| Mazaafrianto et al. | Recent microdevice-based aptamer sensors | |
| Liu et al. | Adaptive two-dimensional microgas chromatography | |
| Bevilacqua et al. | Ricin activity assay by direct analysis in real time mass spectrometry detection of adenine release |