Guevremont et al., 2005 - Google Patents

Comparison of experimental and calculated peak shapes for three cylindrical geometry FAIMS prototypes of differing electrode diameters

Guevremont et al., 2005

View PDF
Document ID
7112109492721159523
Author
Guevremont R
Purves R
Publication year
Publication venue
Journal of the American Society for Mass Spectrometry

External Links

Snippet

High-field asymmetric waveform ion mobility spectrometry (FAIMS) separates ions at atmospheric pressure and room temperature based on the difference of the mobility of ions in strong electric fields and weak electric fields. This field-dependent mobility of an ion is …
Continue reading at link.springer.com (PDF) (other versions)

Classifications

    • GPHYSICS
    • G01MEASURING; TESTING
    • G01NINVESTIGATING OR ANALYSING MATERIALS BY DETERMINING THEIR CHEMICAL OR PHYSICAL PROPERTIES
    • G01N27/00Investigating or analysing materials by the use of electric, electro-chemical, or magnetic means
    • G01N27/62Investigating or analysing materials by the use of electric, electro-chemical, or magnetic means by investigating the ionisation of gases; by investigating electric discharges, e.g. emission of cathode
    • G01N27/622Investigating or analysing materials by the use of electric, electro-chemical, or magnetic means by investigating the ionisation of gases; by investigating electric discharges, e.g. emission of cathode separating and identifying ionized molecules based on their mobility in a carrier gas, i.e. ion mobility spectrometry
    • G01N27/624Investigating or analysing materials by the use of electric, electro-chemical, or magnetic means by investigating the ionisation of gases; by investigating electric discharges, e.g. emission of cathode separating and identifying ionized molecules based on their mobility in a carrier gas, i.e. ion mobility spectrometry using a non-uniform electric field, i.e. differential mobility spectrometry [DMS] or high-field asymmetric-waveform ion-mobility spectrometry [FAIMS]
    • HELECTRICITY
    • H01BASIC ELECTRIC ELEMENTS
    • H01JELECTRIC DISCHARGE TUBES OR DISCHARGE LAMPS
    • H01J49/00Particle spectrometer or separator tubes
    • H01J49/26Mass spectrometers or separator tubes
    • H01J49/34Dynamic spectrometers
    • H01J49/42Stability-of-path spectrometers, e.g. monopole, quadrupole, multipole, farvitrons
    • H01J49/4205Device types
    • H01J49/421Mass filters, i.e. deviating unwanted ions without trapping
    • GPHYSICS
    • G01MEASURING; TESTING
    • G01NINVESTIGATING OR ANALYSING MATERIALS BY DETERMINING THEIR CHEMICAL OR PHYSICAL PROPERTIES
    • G01N27/00Investigating or analysing materials by the use of electric, electro-chemical, or magnetic means
    • G01N27/26Investigating or analysing materials by the use of electric, electro-chemical, or magnetic means by investigating electrochemical variables; by using electrolysis or electrophoresis
    • G01N27/416Systems
    • GPHYSICS
    • G01MEASURING; TESTING
    • G01NINVESTIGATING OR ANALYSING MATERIALS BY DETERMINING THEIR CHEMICAL OR PHYSICAL PROPERTIES
    • G01N30/00Investigating or analysing materials by separation into components using adsorption, absorption or similar phenomena or using ion-exchange, e.g. chromatography or field flow fractionation
    • G01N30/02Column chromatography
    • G01N30/62Detectors specially adapted therefor
    • GPHYSICS
    • G01MEASURING; TESTING
    • G01NINVESTIGATING OR ANALYSING MATERIALS BY DETERMINING THEIR CHEMICAL OR PHYSICAL PROPERTIES
    • G01N33/00Investigating or analysing materials by specific methods not covered by the preceding groups
    • G01N33/48Investigating or analysing materials by specific methods not covered by the preceding groups biological material, e.g. blood, urine; Haemocytometers
    • G01N33/50Chemical analysis of biological material, e.g. blood, urine; Testing involving biospecific ligand binding methods; Immunological testing
    • GPHYSICS
    • G01MEASURING; TESTING
    • G01NINVESTIGATING OR ANALYSING MATERIALS BY DETERMINING THEIR CHEMICAL OR PHYSICAL PROPERTIES
    • G01N27/00Investigating or analysing materials by the use of electric, electro-chemical, or magnetic means
    • G01N27/02Investigating or analysing materials by the use of electric, electro-chemical, or magnetic means by investigating the impedance of the material
    • HELECTRICITY
    • H01BASIC ELECTRIC ELEMENTS
    • H01JELECTRIC DISCHARGE TUBES OR DISCHARGE LAMPS
    • H01J49/00Particle spectrometer or separator tubes
    • H01J49/004Combinations of spectrometers, tandem spectrometers, e.g. MS/MS, MSn
    • H01J49/0045Combinations of spectrometers, tandem spectrometers, e.g. MS/MS, MSn characterised by the fragmentation or other specific reaction

Similar Documents

Publication Publication Date Title
Guevremont et al. Comparison of experimental and calculated peak shapes for three cylindrical geometry FAIMS prototypes of differing electrode diameters
Guevremont et al. Atmospheric pressure ion focusing in a high-field asymmetric waveform ion mobility spectrometer
US7170053B2 (en) Method and apparatus for ion mobility spectrometry with alignment of dipole direction (IMS-ADD)
Rosell-Llompart et al. Sizing nanoparticles and ions with a short differential mobility analyzer
US11532473B2 (en) Mobility and mass measurement using time-varying electric fields
Shvartsburg et al. Modeling the resolution and sensitivity of FAIMS analyses
Shvartsburg et al. Optimization of the design and operation of FAIMS analyzers
US6822224B2 (en) Tandem high field asymmetric waveform ion mobility spectrometry (FAIMS)tandem mass spectrometry
EP2926125B1 (en) Apparatus and method for cross-flow ion mobility spectrometry
US6621077B1 (en) Apparatus and method for atmospheric pressure-3-dimensional ion trapping
Shvartsburg et al. Scaling of the resolving power and sensitivity for planar FAIMS and mobility-based discrimination in flow-and field-driven analyzers
JP2002522873A (en) Apparatus and method for atmospheric pressure three-dimensional ion trapping
Shvartsburg et al. FAIMS operation for realistic gas flow profile and asymmetric waveforms including electronic noise and ripple
Zhou et al. Following the ions through a mass spectrometer with atmospheric pressure interface: simulation of complete ion trajectories from ion source to mass analyzer
Guevremont et al. Atmospheric pressure ion trapping in a tandem FAIMS-FAIMS coupled to a TOFMS: studies with electrospray generated gramicidin S ions
RU2345441C2 (en) Mass spectrometer and appropriate ioniser and methods
Valentine et al. Overtone mobility spectrometry: part 2. Theoretical considerations of resolving power
Allers et al. Negative reactant ion formation in high kinetic energy ion mobility spectrometry (HiKE-IMS)
Guevremont et al. Compensation voltage (CV) peak shapes using a domed FAIMS with the inner electrode translated to various longitudinal positions
Vidal-de-Miguel et al. Transversal modulation ion mobility spectrometry (IMS) coupled with mass spectrometry (MS): exploring the IMS-IMS-MS possibilities of the instrument
Raznikov et al. Ion rotating motion in a gas‐filled radio‐frequency quadrupole ion guide as a new technique for structural and kinetic investigations of ions
Laiko Orthogonal extraction ion mobility spectrometry
Wei et al. Simultaneously improving the resolving power and sensitivity for planar high‐field asymmetric waveform ion mobility spectrometry using a mixed gas inlet mode at two ends
Krasnova et al. Determination of Collisional Cross Section Using Microscale High‐Field Asymmetric Waveform ion Mobility Spectroscopy–Mass Spectrometry (FAIMS‐MS)
Chen Diffusion Constriction of Ions Using Varying Fields for Enhanced Separation, Transmission and Size Range in Ion Mobility Systems