Li et al., 2016 - Google Patents
Data center power minimization with placement optimization of liquid-cooled servers and free air coolingLi et al., 2016
- Document ID
- 7064031162016515390
- Author
- Li L
- Zheng W
- Wang X
- Wang X
- Publication year
- Publication venue
- Sustainable Computing: Informatics and Systems
External Links
Snippet
Most of today's data centers are equipped with servers that rely on air cooling, which is well known to have low cooling efficiency due to undesired air recirculation. As a result, many data centers have started to adopt liquid cooling and free air cooling for improved cooling …
- 238000001816 cooling 0 title abstract description 311
Classifications
-
- G—PHYSICS
- G06—COMPUTING; CALCULATING; COUNTING
- G06F—ELECTRICAL DIGITAL DATA PROCESSING
- G06F1/00—Details of data-processing equipment not covered by groups G06F3/00 - G06F13/00, e.g. cooling, packaging or power supply specially adapted for computer application
- G06F1/26—Power supply means, e.g. regulation thereof
- G06F1/32—Means for saving power
- G06F1/3203—Power Management, i.e. event-based initiation of power-saving mode
- G06F1/3234—Action, measure or step performed to reduce power consumption
- G06F1/3287—Power saving by switching off individual functional units in a computer system, i.e. selective power distribution
-
- G—PHYSICS
- G06—COMPUTING; CALCULATING; COUNTING
- G06F—ELECTRICAL DIGITAL DATA PROCESSING
- G06F1/00—Details of data-processing equipment not covered by groups G06F3/00 - G06F13/00, e.g. cooling, packaging or power supply specially adapted for computer application
- G06F1/16—Constructional details or arrangements
- G06F1/20—Cooling means
- G06F1/206—Cooling means comprising thermal management
-
- G—PHYSICS
- G06—COMPUTING; CALCULATING; COUNTING
- G06F—ELECTRICAL DIGITAL DATA PROCESSING
- G06F1/00—Details of data-processing equipment not covered by groups G06F3/00 - G06F13/00, e.g. cooling, packaging or power supply specially adapted for computer application
- G06F1/16—Constructional details or arrangements
- G06F1/20—Cooling means
- G06F1/203—Cooling means for portable computers, e.g. for laptops
-
- G—PHYSICS
- G06—COMPUTING; CALCULATING; COUNTING
- G06F—ELECTRICAL DIGITAL DATA PROCESSING
- G06F1/00—Details of data-processing equipment not covered by groups G06F3/00 - G06F13/00, e.g. cooling, packaging or power supply specially adapted for computer application
- G06F1/16—Constructional details or arrangements
- G06F1/18—Packaging or power distribution
-
- Y—GENERAL TAGGING OF NEW TECHNOLOGICAL DEVELOPMENTS; GENERAL TAGGING OF CROSS-SECTIONAL TECHNOLOGIES SPANNING OVER SEVERAL SECTIONS OF THE IPC; TECHNICAL SUBJECTS COVERED BY FORMER USPC CROSS-REFERENCE ART COLLECTIONS [XRACs] AND DIGESTS
- Y02—TECHNOLOGIES OR APPLICATIONS FOR MITIGATION OR ADAPTATION AGAINST CLIMATE CHANGE
- Y02B—INDEXING SCHEME RELATING TO CLIMATE CHANGE MITIGATION TECHNOLOGIES RELATED TO BUILDINGS, e.g. INCLUDING HOUSING AND APPLIANCES OR RELATED END-USER APPLICATIONS
- Y02B60/00—Information and communication technologies [ICT] aiming at the reduction of own energy use
- Y02B60/10—Energy efficient computing
- Y02B60/12—Reducing energy-consumption at the single machine level, e.g. processors, personal computers, peripherals, power supply
- Y02B60/1278—Power management
-
- Y—GENERAL TAGGING OF NEW TECHNOLOGICAL DEVELOPMENTS; GENERAL TAGGING OF CROSS-SECTIONAL TECHNOLOGIES SPANNING OVER SEVERAL SECTIONS OF THE IPC; TECHNICAL SUBJECTS COVERED BY FORMER USPC CROSS-REFERENCE ART COLLECTIONS [XRACs] AND DIGESTS
- Y02—TECHNOLOGIES OR APPLICATIONS FOR MITIGATION OR ADAPTATION AGAINST CLIMATE CHANGE
- Y02B—INDEXING SCHEME RELATING TO CLIMATE CHANGE MITIGATION TECHNOLOGIES RELATED TO BUILDINGS, e.g. INCLUDING HOUSING AND APPLIANCES OR RELATED END-USER APPLICATIONS
- Y02B60/00—Information and communication technologies [ICT] aiming at the reduction of own energy use
- Y02B60/10—Energy efficient computing
- Y02B60/12—Reducing energy-consumption at the single machine level, e.g. processors, personal computers, peripherals, power supply
- Y02B60/1275—Cooling means for computing equipment provided with thermal management
-
- G—PHYSICS
- G06—COMPUTING; CALCULATING; COUNTING
- G06F—ELECTRICAL DIGITAL DATA PROCESSING
- G06F17/00—Digital computing or data processing equipment or methods, specially adapted for specific functions
- G06F17/50—Computer-aided design
-
- Y—GENERAL TAGGING OF NEW TECHNOLOGICAL DEVELOPMENTS; GENERAL TAGGING OF CROSS-SECTIONAL TECHNOLOGIES SPANNING OVER SEVERAL SECTIONS OF THE IPC; TECHNICAL SUBJECTS COVERED BY FORMER USPC CROSS-REFERENCE ART COLLECTIONS [XRACs] AND DIGESTS
- Y02—TECHNOLOGIES OR APPLICATIONS FOR MITIGATION OR ADAPTATION AGAINST CLIMATE CHANGE
- Y02B—INDEXING SCHEME RELATING TO CLIMATE CHANGE MITIGATION TECHNOLOGIES RELATED TO BUILDINGS, e.g. INCLUDING HOUSING AND APPLIANCES OR RELATED END-USER APPLICATIONS
- Y02B60/00—Information and communication technologies [ICT] aiming at the reduction of own energy use
- Y02B60/10—Energy efficient computing
- Y02B60/12—Reducing energy-consumption at the single machine level, e.g. processors, personal computers, peripherals, power supply
- Y02B60/1207—Reducing energy-consumption at the single machine level, e.g. processors, personal computers, peripherals, power supply acting upon the main processing unit
- Y02B60/1217—Frequency modification
-
- G—PHYSICS
- G06—COMPUTING; CALCULATING; COUNTING
- G06F—ELECTRICAL DIGITAL DATA PROCESSING
- G06F2217/00—Indexing scheme relating to computer aided design [CAD]
- G06F2217/78—Power analysis and optimization
-
- G—PHYSICS
- G06—COMPUTING; CALCULATING; COUNTING
- G06F—ELECTRICAL DIGITAL DATA PROCESSING
- G06F9/00—Arrangements for programme control, e.g. control unit
- G06F9/06—Arrangements for programme control, e.g. control unit using stored programme, i.e. using internal store of processing equipment to receive and retain programme
- G06F9/46—Multiprogramming arrangements
- G06F9/50—Allocation of resources, e.g. of the central processing unit [CPU]
- G06F9/5094—Allocation of resources, e.g. of the central processing unit [CPU] where the allocation takes into account power or heat criteria
-
- H—ELECTRICITY
- H05—ELECTRIC TECHNIQUES NOT OTHERWISE PROVIDED FOR
- H05K—PRINTED CIRCUITS; CASINGS OR CONSTRUCTIONAL DETAILS OF ELECTRIC APPARATUS; MANUFACTURE OF ASSEMBLAGES OF ELECTRICAL COMPONENTS
- H05K7/00—Constructional details common to different types of electric apparatus
- H05K7/20—Modifications to facilitate cooling, ventilating, or heating
- H05K7/20709—Modifications to facilitate cooling, ventilating, or heating for server racks or cabinets; for data centers, e.g. 19-inch computer racks
- H05K7/20718—Forced ventilation of a gaseous coolant
- H05K7/20745—Forced ventilation of a gaseous coolant within rooms for removing heat from cabinets, e.g. by air conditioning device
Similar Documents
Publication | Publication Date | Title |
---|---|---|
Li et al. | Data center power minimization with placement optimization of liquid-cooled servers and free air cooling | |
Ahmad et al. | Joint optimization of idle and cooling power in data centers while maintaining response time | |
US9445529B2 (en) | Liquid cooled data center design selection | |
AU2011289409B2 (en) | System and method for predicting transient cooling performance for data center | |
Lee et al. | Proactive thermal management in green datacenters | |
Tang et al. | Thermal-aware task scheduling to minimize energy usage of blade server based datacenters | |
MirhoseiniNejad et al. | Holistic thermal-aware workload management and infrastructure control for heterogeneous data centers using machine learning | |
Li et al. | Coordinating liquid and free air cooling with workload allocation for data center power minimization | |
Sun et al. | Energy-efficient and thermal-aware resource management for heterogeneous datacenters | |
Yeo et al. | ATAC: Ambient temperature-aware capping for power efficient datacenters | |
Mukherjee et al. | A detailed study on data centre energy efficiency and efficient cooling techniques | |
Oxley et al. | Rate-based thermal, power, and co-location aware resource management for heterogeneous data centers | |
Varsamopoulos et al. | Energy efficiency of thermal-aware job scheduling algorithms under various cooling models | |
Conficoni et al. | Integrated energy-aware management of supercomputer hybrid cooling systems | |
Yeo et al. | SimWare: A holistic warehouse-scale computer simulator | |
Athavale et al. | Genetic algorithm based cooling energy optimization of data centers | |
Modi et al. | Experimental Investigation of the Impact of Improved Ducting and Chassis Re-Design of a Hybrid-Cooled Server | |
Li et al. | Placement optimization of liquid-cooled servers for power minimization in data centers | |
Chaudhry et al. | Thermal-aware relocation of servers in green data centers | |
Zhang et al. | Steady and transient behavior of data centers with variations in thermal load and environmental conditions | |
Moore et al. | Going beyond CPUs: The potential of temperature-aware solutions for the data center | |
EP2575003B1 (en) | Method for determining assignment of loads of data center and information processing system | |
Zhao et al. | A smart coordinated temperature feedback controller for energy-efficient data centers | |
Rajamani et al. | Power management for computer systems and datacenters | |
Han et al. | Thermal-aware energy-efficient task scheduling for DVFS-enabled data centers |