[go: up one dir, main page]

Al-Bakeri et al., 1993 - Google Patents

Experimental optimization of sponge ball cleaning system operation in Umm AI Nar MSF desalination plants

Al-Bakeri et al., 1993

Document ID
6659612051182359022
Author
Al-Bakeri F
El Hares H
Publication year
Publication venue
Desalination

External Links

Snippet

This paper discusses the on-line condenser tube cleaning system and some of the difficulties encountered during operation. Procedures are suggested for obtaining optimum parameters (number of operating balls per tube, number of cycles per day, overall permitted …
Continue reading at www.sciencedirect.com (other versions)

Similar Documents

Publication Publication Date Title
CA2149452C (en) Method and apparatus for cleaning tubes of heat exchangers
Al-Bakeri et al. Experimental optimization of sponge ball cleaning system operation in Umm AI Nar MSF desalination plants
Lestina Heat exchangers fouling, cleaning, and maintenance
Rice et al. THRESHOLD TREATMENT Elimination of Calcium Carbonate Deposits from Indutrials waters
Al-Bakeri et al. Optimization of sponge ball cleaning system operation and design in MSF plants
TW540069B (en) Method for controlling water quality in nuclear reactor and nuclear power generation equipment
US4373572A (en) Commercial laundry heat recovery system
EP3661879B1 (en) Grey water heat recovery system and method
Böhmer On-load tube cleaning systems and debris filters for avoidance of micro-and macrofouling in MSF desalination plants
DE2911809C2 (en) Method and device for removing deposits and / or deposits from a cooling system
Novak Fouling in plate heat exchangers and its reduction by proper design
KR100775293B1 (en) Pitch removal device included in deionized water after ammonia distillation column
Kitzman et al. Chemical vs. non-chemical cooling water treatments–a side-by-side comparison
CN223490522U (en) A system for preventing frozen brine blockage
Henager et al. Engineering factors influencing Corbicula fouling in nuclear-service water systems
Leung et al. Sponge-ball automatic tube cleaning device for saving energy in a chiller
Hale Managing Fouling in Heat Exchangers: Fouling of heat exchanger surfaces reduces thermal efficiency. An improved understanding of fouling and the design factors that affect it can help ensure that heat exchange occurs during normal operating conditions.
Tuthill The right metal for heat exchanger tubes
Bour-Beucler Commissioning, operation cleaning and maintenance
Harbaugh Experiences with Cleaning Stainless Steel Condensers on Allegheny
JPH0477127B2 (en)
JPS605838B2 (en) Dust removal method and device for cooling water introduction pipes of steam turbine condensers, etc.
Axsom On-Stream Cleaning Pays off
Anastas et al. Geothermal Loop Experimental Facility. Quarterly report, January-March, 1979
Holland et al. A Case History in Cooling Water Treatment