Ultra-stable sapphire resonator-oscillatorLuiten et al., 2002
- Document ID
- 6216240933400356032
- Author
- Luiten A
- Mann A
- Giles A
- Blair D
- Publication year
- Publication venue
- IEEE Transactions on Instrumentation and Measurement
External Links
Snippet
Preliminary measurements of the properties of cryogenic sapphire resonators with various concentrations of paramagnetic impurities are reported. These resonators are mounted in both copper and niobium shields. It is found that one can achieve extrema in the frequency …
- 229910052594 sapphire 0 title abstract description 27
Classifications
-
- G—PHYSICS
- G01—MEASURING; TESTING
- G01R—MEASURING ELECTRIC VARIABLES; MEASURING MAGNETIC VARIABLES
- G01R33/00—Arrangements or instruments for measuring magnetic variables
- G01R33/20—Arrangements or instruments for measuring magnetic variables involving magnetic resonance
- G01R33/28—Details of apparatus provided for in groups G01R33/44 - G01R33/64
- G01R33/32—Excitation or detection systems, e.g. using radio frequency signals
- G01R33/34—Constructional details, e.g. resonators, specially adapted to MR
- G01R33/34015—Temperature-controlled RF coils
-
- G—PHYSICS
- G01—MEASURING; TESTING
- G01R—MEASURING ELECTRIC VARIABLES; MEASURING MAGNETIC VARIABLES
- G01R33/00—Arrangements or instruments for measuring magnetic variables
- G01R33/20—Arrangements or instruments for measuring magnetic variables involving magnetic resonance
- G01R33/28—Details of apparatus provided for in groups G01R33/44 - G01R33/64
- G01R33/32—Excitation or detection systems, e.g. using radio frequency signals
- G01R33/34—Constructional details, e.g. resonators, specially adapted to MR
- G01R33/345—Constructional details, e.g. resonators, specially adapted to MR of waveguide type
- G01R33/3453—Transverse electromagnetic [TEM] coils
-
- G—PHYSICS
- G01—MEASURING; TESTING
- G01R—MEASURING ELECTRIC VARIABLES; MEASURING MAGNETIC VARIABLES
- G01R33/00—Arrangements or instruments for measuring magnetic variables
- G01R33/20—Arrangements or instruments for measuring magnetic variables involving magnetic resonance
- G01R33/28—Details of apparatus provided for in groups G01R33/44 - G01R33/64
- G01R33/38—Systems for generation, homogenisation or stabilisation of the main or gradient magnetic field
- G01R33/389—Field stabilisation, e.g. by field measurements and control means or indirectly by current stabilisation
-
- G—PHYSICS
- G01—MEASURING; TESTING
- G01R—MEASURING ELECTRIC VARIABLES; MEASURING MAGNETIC VARIABLES
- G01R33/00—Arrangements or instruments for measuring magnetic variables
- G01R33/20—Arrangements or instruments for measuring magnetic variables involving magnetic resonance
- G01R33/28—Details of apparatus provided for in groups G01R33/44 - G01R33/64
- G01R33/32—Excitation or detection systems, e.g. using radio frequency signals
- G01R33/36—Electrical details, e.g. matching or coupling of the coil to the receiver
- G01R33/3628—Tuning/matching of the transmit/receive coil
- G01R33/3635—Multi-frequency operation
-
- G—PHYSICS
- G01—MEASURING; TESTING
- G01R—MEASURING ELECTRIC VARIABLES; MEASURING MAGNETIC VARIABLES
- G01R33/00—Arrangements or instruments for measuring magnetic variables
- G01R33/20—Arrangements or instruments for measuring magnetic variables involving magnetic resonance
- G01R33/24—Arrangements or instruments for measuring magnetic variables involving magnetic resonance for measuring direction or magnitude of magnetic fields or magnetic flux
-
- G—PHYSICS
- G01—MEASURING; TESTING
- G01R—MEASURING ELECTRIC VARIABLES; MEASURING MAGNETIC VARIABLES
- G01R33/00—Arrangements or instruments for measuring magnetic variables
- G01R33/20—Arrangements or instruments for measuring magnetic variables involving magnetic resonance
- G01R33/60—Arrangements or instruments for measuring magnetic variables involving magnetic resonance using electron paramagnetic resonance
Similar Documents
| Publication | Publication Date | Title |
|---|---|---|
| Johnson et al. | Antiferromagnetic resonance in Mn F 2 | |
| Luiten et al. | Power stabilized cryogenic sapphire oscillator | |
| Mann et al. | Cryogenic sapphire oscillator with exceptionally high frequency stability | |
| Luiten et al. | Ultra-stable sapphire resonator-oscillator | |
| Hartnett et al. | Frequency-temperature compensation in Ti/sup 3+/and Ti/sup 4+/doped sapphire whispering gallery mode resonators | |
| Dick et al. | Temperature-compensated sapphire resonator for ultra-stable oscillator capability at temperatures above 77 K | |
| Tobar et al. | Dielectric frequency-temperature-compensated microwave whispering-gallery-mode resonators | |
| US20210263117A1 (en) | Oscillator-based Solid-State Spin Sensor | |
| Dick et al. | Ultra-stable performance of the superconducting cavity maser | |
| Hagiwara et al. | A complete frequency-field chart for the antiferromagnetic resonance in MnF2 | |
| Strandberg | Recording magnetic-resonance spectrometer | |
| Driscoll et al. | Cooled, ultrahigh Q, sapphire dielectric resonators for low-noise, microwave signal generation | |
| Bourgeois et al. | A cryogenic open-cavity sapphire reference oscillator with low spurious mode density | |
| Blair et al. | High-Q microwave properties of a sapphire ring resonator | |
| Wang et al. | Improved performance of the superconducting cavity maser at short measuring times (atomic frequency standards) | |
| Luiten et al. | Improved sapphire dielectric resonators for ultrastable oscillators | |
| Dymanus | High‐Q Stark Cavity Absorption Cell for Microwave Spectrometers | |
| Hartnett et al. | Frequency-temperature compensation techniques for high-Q microwave resonators | |
| Hao et al. | Temperature compensated cryogenic whispering gallery mode resonator for microwave frequency standard applications | |
| Hartnett et al. | Anisotropic paramagnetic susceptibility of crystalline ruby at cryogenic temperatures | |
| Alimenti et al. | Cryogenic characterization of microwave devices | |
| Dick et al. | Temperature compensated sapphire resonator for ultra-stable oscillator capability at temperatures above 77 kelvin | |
| Kovacich et al. | Magnetic field tuning of paramagnetic frequency-temperature compensation in cryogenic sapphire dielectric microwave resonators | |
| Luiten et al. | Cryogenic sapphire resonator-oscillator with exceptional stability: an update | |
| Kersalé et al. | Cryogenic monolithic sapphire-rutile temperature compensated resonator oscillator |