Daube-Witherspoon et al., 1987 - Google Patents
Treatment of axial data in three-dimensional PETDaube-Witherspoon et al., 1987
View PDF- Document ID
- 4314459923656574849
- Author
- Daube-Witherspoon M
- Muehllehner G
- Publication year
- Publication venue
- Journal of nuclear medicine
External Links
Snippet
Improved axial spatial resolution in positron emission tomography (PET) scanners will lead to reduced sensitivity unless the axial acceptance angle for the coincidences is kept constant. A large acceptance angle, however, violates assumptions made in most …
- 230000000694 effects 0 abstract description 17
Classifications
-
- G—PHYSICS
- G06—COMPUTING; CALCULATING; COUNTING
- G06T—IMAGE DATA PROCESSING OR GENERATION, IN GENERAL
- G06T11/00—2D [Two Dimensional] image generation
- G06T11/003—Reconstruction from projections, e.g. tomography
- G06T11/005—Specific pre-processing for tomographic reconstruction, e.g. calibration, source positioning, rebinning, scatter correction, retrospective gating
-
- G—PHYSICS
- G06—COMPUTING; CALCULATING; COUNTING
- G06T—IMAGE DATA PROCESSING OR GENERATION, IN GENERAL
- G06T11/00—2D [Two Dimensional] image generation
- G06T11/003—Reconstruction from projections, e.g. tomography
- G06T11/006—Inverse problem, transformation from projection-space into object-space, e.g. transform methods, back-projection, algebraic methods
-
- G—PHYSICS
- G01—MEASURING; TESTING
- G01T—MEASUREMENT OF NUCLEAR OR X-RADIATION
- G01T1/00—Measuring X-radiation, gamma radiation, corpuscular radiation, or cosmic radiation
- G01T1/16—Measuring radiation intensity
- G01T1/161—Application in the field of nuclear medicine, e.g. in vivo counting
- G01T1/164—Scintigraphy
- G01T1/1641—Static instruments for imaging the distribution of radioactivity in one or two dimensions using one or several scintillating elements; Radio-isotope cameras
- G01T1/1648—Ancillary equipment for scintillation cameras, e.g. reference markers, devices for removing motion artifacts, calibration devices
-
- G—PHYSICS
- G01—MEASURING; TESTING
- G01T—MEASUREMENT OF NUCLEAR OR X-RADIATION
- G01T1/00—Measuring X-radiation, gamma radiation, corpuscular radiation, or cosmic radiation
- G01T1/29—Measurement performed on radiation beams, e.g. position or section of the beam; Measurement of spatial distribution of radiation
- G01T1/2914—Measurement of spatial distribution of radiation
- G01T1/2985—In depth localisation, e.g. using positron emitters; Tomographic imaging (longitudinal and transverse section imaging; apparatus for radiation diagnosis sequentially in different planes, steroscopic radiation diagnosis)
-
- G—PHYSICS
- G01—MEASURING; TESTING
- G01T—MEASUREMENT OF NUCLEAR OR X-RADIATION
- G01T1/00—Measuring X-radiation, gamma radiation, corpuscular radiation, or cosmic radiation
- G01T1/16—Measuring radiation intensity
- G01T1/161—Application in the field of nuclear medicine, e.g. in vivo counting
- G01T1/164—Scintigraphy
- G01T1/1641—Static instruments for imaging the distribution of radioactivity in one or two dimensions using one or several scintillating elements; Radio-isotope cameras
- G01T1/1647—Processing of scintigraphic data
-
- G—PHYSICS
- G06—COMPUTING; CALCULATING; COUNTING
- G06T—IMAGE DATA PROCESSING OR GENERATION, IN GENERAL
- G06T2211/00—Image generation
- G06T2211/40—Computed tomography
-
- G—PHYSICS
- G06—COMPUTING; CALCULATING; COUNTING
- G06T—IMAGE DATA PROCESSING OR GENERATION, IN GENERAL
- G06T2207/00—Indexing scheme for image analysis or image enhancement
- G06T2207/30—Subject of image; Context of image processing
- G06T2207/30004—Biomedical image processing
-
- G—PHYSICS
- G06—COMPUTING; CALCULATING; COUNTING
- G06T—IMAGE DATA PROCESSING OR GENERATION, IN GENERAL
- G06T2207/00—Indexing scheme for image analysis or image enhancement
- G06T2207/10—Image acquisition modality
- G06T2207/10072—Tomographic images
- G06T2207/10084—Hybrid tomography; Concurrent acquisition with multiple different tomographic modalities
Similar Documents
| Publication | Publication Date | Title |
|---|---|---|
| Daube-Witherspoon et al. | Treatment of axial data in three-dimensional PET | |
| Merlin et al. | CASToR: a generic data organization and processing code framework for multi-modal and multi-dimensional tomographic reconstruction | |
| Zeng et al. | Three-dimensional iterative reconstruction algorithms with attenuation and geometric point response correction | |
| Hong et al. | Ultra fast symmetry and SIMD-based projection-backprojection (SSP) algorithm for 3-D PET image reconstruction | |
| Kinahan et al. | Analytic 3 D image reconstruction using all detected events | |
| Reader et al. | EM algorithm system modeling by image-space techniques for PET reconstruction | |
| Bowsher et al. | Treatment of Compton scattering in maximum-likelihood, expectation-maximization reconstructions of SPECT images | |
| Zhou et al. | Fast and efficient fully 3D PET image reconstruction using sparse system matrix factorization with GPU acceleration | |
| Levkovilz et al. | The design and implementation of COSEN, an iterative algorithm for fully 3-D listmode data | |
| US8509504B2 (en) | Point spread function radial component implementation in Joseph's forward projector | |
| Zhang et al. | Penalized maximum-likelihood reconstruction for improving limited-angle artifacts in a dedicated head and neck PET system | |
| Brasse et al. | Fast fully 3-D image reconstruction in PET using planograms | |
| Hamill et al. | Energy‐based scatter estimation in clinical PET | |
| US20030190065A1 (en) | Fast iterative image reconstruction from linograms | |
| Keesing et al. | Image reconstruction and system modeling techniques for virtual-pinhole PET insert systems | |
| McKee et al. | A deconvolution scatter correction for a 3-D PET system | |
| Tsui et al. | Analytic image reconstruction methods in emission computed tomography | |
| Goertzen et al. | Effect of phantom voxelization in CT simulations | |
| Zeng et al. | Iterative reconstruction with attenuation compensation from cone-beam projections acquired via nonplanar orbits | |
| Chen et al. | A nonlinear spatially variant object-dependent system model for prediction of partial volume effects and scatter in PET | |
| Hsieh et al. | Projection space image reconstruction using strip functions to calculate pixels more" natural" for modeling the geometric response of the SPECT collimator | |
| Liang et al. | Quantitative brain SPECT in three dimensions: an analytical approach without transmission scans | |
| Vandenberghe et al. | Iterative list mode reconstruction for coincidence data of gamma camera | |
| Glick et al. | Compensation for nonuniform attenuation in SPECT brain imaging | |
| Hamill et al. | Iterative reconstruction methods for high-throughput PET tomographs |