[go: up one dir, main page]

Lenntech Water treatment & purification Lenntech Water treatment & purification

Instrumentation & sensors

Check our pages on ozone and ClO2 measuring devices:

Ozone measurement

Chlorine dioxide measurement

The AQL Ozone family 

Portable measurement:

- Conductivity
- Iron, Manganese, Sulfates, Nitrates
- COD
- pH
- Oxygen
- Ozone
- Chlorine dioxide
- Complete portable water laboratory

Other common in-line transmitters:

- Conductivity
- Resistivity
- Turbidity
- Hardness - Testomat
- SDI
- pH
- Flow (magnetic or ultrasonic)
- Pressure
- Temperature

Lenntech also provides instrument controllers for integrated process control.

 

A-22 Ozone Sensor

Rugged & Versatile

Autoranging .030-1.999 ppm and 2.0-20.00 ppm

10% accuracy. T and RH compensated

Data port for external data logger such as our DL-3

USB, 4-20 mA, 0-2 VDC outputs for loggers, computers and PLC

Size 108 W × 222 L × 64 D mm,

Weight 0.71 kg

Power source: Internal rechargeable batteries or 12-24 VDC, 500 mA, from external adapter/charger

DO-3 Ozone Monitor

Range: 0.00 – 5.00 mg/L

Operating temperature 0-40 °C (32 - 105°F)

Recommemnded water temp: 20 - 30 °C (68 - 86 °F)

Accuracy: within 20% when operated near room temperature

Interferences: Dissolved Chlorine

Alarms: Buzzer

Self-test on Start-up

Size 79.5 W x 39.6 L x 34.5 D mm

Weight 0.49 kg

DOM-1 Ozone Monitor

Range: 0 - 2 ppm

4 - 20mA output tp PLC or other controller

Accurancy: better than 20%, 10% typical

Power supply: 12VDC - 800mA

OG-3 Ozone callibration checker

Ozone source: UV lamp

Output concentration 0.1 ppm,         max 1 ppm

Accurancy: 10%

Power supply: 12 VDC - 300 mA

Size: 160 x 95 x 36 mm

Weight: 225 g

Alarm Devices

RAP-2 Remote ALarm Panel

Input: 0 - 2 VDC , 4 - 20 mA

Very Bright Red Strobe Light

Alarm Set-point adjustable

Output: 4 - 20 mA or Relais

Power supply: 14 - 30 VAC or DC

Size: 125 x 175 x 77 mm

SAT-1 Signal Alarm Tower

Light indicator: Green, Amber, Red

Audible: Slow-, Fast Pulse 85 dB at 1m

Power supply: 24 VDC - 350 mA

Software

DL-SC3 Data Logging Software

Specially for OS-4, OS-6, SM-4, SM-6, A-22 and UV-100

Log real-time  measurements to a filewith date & time stamps

Compatible with Windows XP, Windows 7

Needs DL-C3, RS 232 Cable set

 

DL-C3 Communication Cable set RS-232 including USB to Serial adapter

For a direct quotation, please contact us: Feedback Form or call us on +31 152 610 900

Lenntech (European Head Office)

Distributieweg 3
2645 EG Delfgauw
The Netherlands
Phone: +31 152 610 900
fax: +31 152 616 289
e-mail: info@lenntech.com


Lenntech USA LLC (Americas)

5975 Sunset Drive
South Miami, FL 33143
USA
Phone: +1 877 453 8095
e-mail: info@lenntech.com


Lenntech DMCC (Middle East)

Level 6 - OFFICE #101-One JLT Tower
Jumeirah Lake Towers
Dubai - U.A.E.
Phone: +971 4 429 5853
e-mail: info@lenntech.com



Lenntech terms of business are according to Orgalime SI 24 conditions. A copy can be provided on request.

Copyright © 1998-2025 Lenntech B.V. All rights reserved